GSTA
GSTA-duct-mountNO2-replacement-sensorCO-replacement-sensorA-507-calibration-adapterA-449-RemoteLCD-Display

Dwyer Series GSTA Carbon Monoxide/Nitrogen Dioxide Gas Transmitter

$ 175.00$ 375.00

Clear selection

Accessories

Product Description

High Accuracy Electrochemical Sensor, Universal Output

The Series GSTA Carbon Monoxide/Nitrogen Dioxide Transmitters monitor the gas concentration in underground parking garages and loading docks. Carbon monoxide is commonly used to measure the exhaust of gasoline engines, while nitrogen dioxide is used for diesel engines. Field selectable current and voltage outputs allow the transmitter to be used with almost any building management controller. For carbon monoxide units, the user can select the output range to be from 0 to 50 ppm or up to 0 to 500 ppm. Nitrogen dioxide units come with a standard 0 to 10 ppm range. The output can be inverted to read 20 to 4 mA or 10 (5) to 0 VDC using internal dip switches.

To maximize the accuracy of the Series GSTA, the sensor can be field-calibrated using the A-449 remote LCD display. When the sensor reaches the end of its life, the display will indicate that the sensor needs to be replaced.

Models

Model Description
GSTA-C Carbon Monoxide Transmitter with Universal Current/Voltage Outputs
GSTA-C-D Carbon Monoxide Duct Mount Transmitter with Universal Current/Voltage Outputs
GSTA-N Nitrogen Dioxide Transmitter with Universal Current / Voltage Outputs
GSTA-N-D Nitrogen Dioxide Duct Mount Transmitter with Universal Current/Voltage Outputs

Specifications

Sensor:
Field replaceable electrochemical, 4 years typical lifespan.
Recommend calibration every 6 months.
Range:
CO: switch selectable 200 or 500 ppm; NO2:10 ppm.
Output Drift:
<5% per year in air.
Coverage Area:
5000 to 7500 sq ft typical.
Accuracy:
CO=2% of reading, NO2=3% at the time of calibration.
Resolution:
CO=1 ppm
Temperature Limits::
>Ambient: -4 to 122°F (-20 to 50°C);

Storage: For best sensor life, 32 to 68°F (0 to 20°C).
Humidity Limits:
15 to 90% RH constant; 0 to 99% RH intermittent.
Response Time:
<45 seconds to 90% CO, <25 to 90% NO2.
Span and Zero Adjustment:
Via pushbutton, using optional A-449
display.
Housing:
UV resistant glass filled polycarbonate.
Output:
Switch selectable 4 to 20 mA (loop powered), 0 to 5 V @ 5 mA, or 0
to 10 V@ 5 mA;
Switch selectable 0 to 5 V / 1 to 5 V and 0 to 10 V / 2 to 10 V;
Switch selectable normal or reverse output.
Power Supply:
Current output=10 to 35 VDC;
Voltage output=15 to 35 VDC or 15 to 29 VAC.
Electrical Connection:
Removable terminal block, knocks out for
conduit fitting.
Calibration:
Via pushbuttons using A-449 auxiliary display. Span gas
concentration is field selectable.
Weight:
1 lb (.45 kg).
Agency Approvals:
CE.

Literature

Manuals

Catalog Pages

Series GSTA Catalog Page

Features

Add optional integral LCD display by adding -LCD to end of model number (Example: GSTA-C-LCD)

Approvals

CE Approval

Drawings

Accessories

Model Number Description
Remote display with mini USB display. A-449 Remote display with mini USB display.
Replacement Carbon Monoxide Sensor for GSTA Series, Model CMT200 A-505 Replacement Carbon Monoxide Sensor for GSTA Series, Model CMT200
Replacement Nitrogen Dioxide Sensor for GSTA Series A-506 Replacement Nitrogen Dioxide Sensor for GSTA Series
Gas calibration Kit for GSTA Series A-507 Gas calibration Kit for GSTA Series
Gas Calibration Kit (GROUND SHIPMENTS ONLY) GCK-200CO-2000CO2 Gas Calibration Kit (GROUND SHIPMENTS ONLY)

Model Chart

EXAMPLE GSTA C D Series GSTA-C-D, Carbon Monoxide Transmitter, CO Carbon Monoxide, duct mount
SERIES GSTA     Carbon Monoxide Gas Transmitter
GAS TYPE   C
N
  CO Carbon Monoxide
Nitrogen Dioxide
OPTIONS     D
LCD
Duct Mount
LCD Display